[COMSOL_Users] Digest Number 1526

Messages In This Digest (3 Messages)

1a.
Re: Same old _ out of memory From: ta_wan2006
1b.
Re: Same old _ out of memory From: freelsjd32289
2a.
error 4100 From: Saskia Roels

Messages

1a.

Re: Same old _ out of memory

Posted by: "ta_wan2006" ta_wan2006@yahoo.com.tw   ta_wan2006

Mon Jan 5, 2009 8:58 pm (PST)

Thank you!! My computer OS is 32bits with WinXP Professional SP3,
When I open [boot loader] its shown
[boot loader]
timeout=5
default=multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
[operating systems]
multi(0)disk(0)rdisk(0)partition(1)\WINDOWS="Microsoft Windows XP
Professional" /noexecute=optin /fastdetect /noexecute=alwaysoff

This is different what you describes. Where I should put the /3G
parameter?

In X:\COMSOL35\bin\comsol.opts
# memory size parameters
MAXHEAP=256m
MAXHEAPCLIENT=512m
MAXHEAPSERVER=256m
MAXHEAP64=1024m
MAXHEAPCLIENT64=1024m
MAXHEAPSERVER64=1024m
STACKSIZE=2m
STACKSIZE64=4m
JAVAOPTS=on
I just need to change MAXHEAP=256m to MAXHEAP=128m?

--- In COMSOL_Users@yahoogroups.com, "freelsjd32289" <freelsjd@...>
wrote:
>
> --- In COMSOL_Users@yahoogroups.com, "freelsjd32289" <freelsjd@>
wrote:
> >
> > --- In COMSOL_Users@yahoogroups.com, "ta_wan2006" <ta_wan2006@>
wrote:
> > >
> > > I hate to say that-- when the solver pop up #### out of memory.
It is
> > > realy made me mad about that. I have been used many commercial
> > > software. The most and frequently to see the small reply
window "####
> > > out of memory" should be Comsol. Is the user problems or the
software-
> > > itself problem?
> > >
> >
> > 32bit or 64bit ?
> >
> > what kind of solver are you using ?
> >
>
> See the following help available to registered COMSOL users:
>
> http://www.comsol.com/support/knowledgebase/1030/
>
> Solution Number: 1030
> Title: Error message: "Out of memory"
> Platform: All Platforms
> Applies to: All Products
> Versions: 3.3, 3.4
> Created: April 29, 2008
> Last Modified: August 15, 2008
> Categories: Solver, Postprocessing, Error Messages
> Keywords: memory, geometry, mesh
> Description
>
> The error message "Out of memory" occurs mostly on 32-bit platforms,
> due to the inherent limit in memory address space. We recommend a
> 64-bit system (for example Windows XP 64-bit Edition, Vista 64-bit
or
> a 64-bit Linux version) for any user with sizable models. For those
> users who are still restricted to a 32-bit platform, this Knowledge
> Base solution will give some guidance how to get the most out of
your
> system.
> Introduction
>
> A 32-bit processor system (for example Windows XP) can potentially
> allocate up to 4 GB of memory, but in most practical cases only 1.5
GB
> due to operating system footprint. This is regardless of how big you
> set the swap space. Some 32-bit operating systems require special
> settings to be able to use high amounts of memory.
> Software Settings
>
> There are several ways of increasing the available memory for the
solvers.
> Tuning the Java heap size
>
> Of the available memory (RAM and virtual memory), one section, the
> Java heap, is reserved for Java and will be used for graphics and
> postprocessing. The rest will be available for meshing and solving.
If
> the out-of-memory message appears during the solution progress, you
> can decrease the Java heap size. If you get out-of-memory during
> postprocessing, increase the Java heap.
>
> On Windows, modify the file COMSOL34/bin/comsol.opts and on
> Sun/Linux/Mac OSX, modify the file COMSOL34/bin/comsol. Change the
> line MAXHEAP=256m to for example MAXHEAP=128m. You need to restart
> COMSOL for the change to apply.
> Running client-server mode
>
> Sometimes it can be favorable to run client/server mode because a
> separate server has less memory fragmentation problems. If you want
to
> change the Java heap on a COMSOL server, follow the intstructions
> above but modify the MAXHEAPSERVER line instead.
> Running COMSOL with MATLAB
>
> Similarly, if you run out of memory while saving an mph-file from
the
> COMSOL with MATLAB, change the value of the MAXHEAPSERVER line.
> Virtual Memory and Swap Space for 32-bit architecture
>
> Increasing the swap file size on the system is only interesting if
you
> can live with the notable slowness in operation that occurs as soon
as
> the hard disk swapping starts. In many cases, hard disk swapping is
> not an option.
>
> In Windows XP, you only have 2 GB of virtual address space available
> initially for a user process. This memory space is also sometimes
> fragmented by shared libraries. On Linux, Sun, and Mac, you
typically
> get between 3-4 GB of virtual address space available for your
> process. This address space is usually not fragmented.
> 3 GB switch
>
> COMSOL Multiphysics supports the option in Windows XP Professional
and
> Windows 2003 Server to have 3 GB of virtual address space available
> for user processes. This reduces the available address space for the
> operating system to 1 GB. To access it you must boot the system
using
> an additional boot parameter. The following example shows how to
> enable application memory tuning by adding the /3GB parameter in the
> boot.ini file:
>
> Caution: Only add the /3GB switch, shown in boldface below. Do not
> copy the full lines below into your boot.ini, since the parameter
> values may be different for different systems. Please note that the
> file boot.ini is critical to booting your system. If you change the
> partition numbers, your computer will fail to boot and you cannot
> recover the system without a system restore disk.
>
> To open the boot.ini file on Windows XP Professional, right-click My
> Computer, select the Advanced tab, go to the lower section Startup
and
> Recovery, click Settings. In the new dialog box, click Edit.
>
> [boot loader]
> timeout=30
> default=multi(0)disk(0)rdisk(0)partition(2)\WINNT
> [operating systems]
> multi(0)disk(0)rdisk(0)partition(2)\WINNT="????" /3GB
>
> The "????" above can be the name of your operating system for
example
> "Microsoft Windows XP Professional".
>
> Some users report that Vista 32-bit also can benefit from a 3 GB
> setting. This is not tested by us. To change the setting, run the
> command bcdedit /set IncreaseUserVa 3072 as an administrator at the
> command prompt. To turn off the 3 GB switch, run
bcdedit /deletevalue
> IncreaseUserVa.
> A Note about Memory Monitoring on 32-bit systems
>
>
> Especially in 3D modelling, extensive memory usage urges some extra
> precautions. The "Out of Memory"-problem occurs whenever COMSOL
> Multiphysics tries to allocate an array which does not fit
> sequentially in memory. It is common on 32-bit systems that the
amount
> of available memory seems large enough for the array—but there may
> exist no continuous block of that size due to fragmentation. If you
> for example look in the task manager of Windows, this may have the
> effect that you can't see any high memory allocation, and get "out
of
> memory" anyway.
>
> The "Memory Usage" column in the Windows task manager can also be
> misleading, because it only shows the currently swapped portion. A
> better indicator of total usage can be found like this (Win2000,
> WinNT, Win XP, Windows Vista):
>
> 1. Press Ctrl-Alt-Delete to bring up the Task Manager.
> 2. Go to the "processes" tab.
> 3. From the View menu, choose Select Columns.
> 4. Select the Virtual Memory Size (in Windows Vista: "Commit Size")
> check box.
> 5. Now find the comsol.exe process that corresponds to the COMSOL
> Multiphysics process in the process list and look in the "VM Size"
> column. This shows a better value for the actual memory used.
>
> See also: Knowledge Base solution 866 for hardware tips, Knowledge
> Base solution 830 about memory intensive models.
>

1b.

Re: Same old _ out of memory

Posted by: "freelsjd32289" freelsjd@ornl.gov   freelsjd32289

Tue Jan 6, 2009 12:06 pm (PST)

You should not need to modify your boot loader at all !

We are just talking about how you start up COMSOL !

The /3G switch is just that--a switch you add to the end of the comsol
execution line. So, in your icon properties, where the command is
defined, add the /3G switch.

The other parameters are changes to the COMSOL options file. You may
need to experiment with your settings, following the COMSOL
recommendations.

--- In COMSOL_Users@yahoogroups.com, "ta_wan2006" <ta_wan2006@...> wrote:
>
> Thank you!! My computer OS is 32bits with WinXP Professional SP3,
> When I open [boot loader] its shown
> [boot loader]
> timeout=5
> default=multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
> [operating systems]
> multi(0)disk(0)rdisk(0)partition(1)\WINDOWS="Microsoft Windows XP
> Professional" /noexecute=optin /fastdetect /noexecute=alwaysoff
>
> This is different what you describes. Where I should put the /3G
> parameter?
>
> In X:\COMSOL35\bin\comsol.opts
> # memory size parameters
> MAXHEAP=256m
> MAXHEAPCLIENT=512m
> MAXHEAPSERVER=256m
> MAXHEAP64=1024m
> MAXHEAPCLIENT64=1024m
> MAXHEAPSERVER64=1024m
> STACKSIZE=2m
> STACKSIZE64=4m
> JAVAOPTS=on
> I just need to change MAXHEAP=256m to MAXHEAP=128m?
>
>
>
>
> --- In COMSOL_Users@yahoogroups.com, "freelsjd32289" <freelsjd@>
> wrote:
> >
> > --- In COMSOL_Users@yahoogroups.com, "freelsjd32289" <freelsjd@>
> wrote:
> > >
> > > --- In COMSOL_Users@yahoogroups.com, "ta_wan2006" <ta_wan2006@>
> wrote:
> > > >
> > > > I hate to say that-- when the solver pop up #### out of memory.
> It is
> > > > realy made me mad about that. I have been used many commercial
> > > > software. The most and frequently to see the small reply
> window "####
> > > > out of memory" should be Comsol. Is the user problems or the
> software-
> > > > itself problem?
> > > >
> > >
> > > 32bit or 64bit ?
> > >
> > > what kind of solver are you using ?
> > >
> >
> > See the following help available to registered COMSOL users:
> >
> > http://www.comsol.com/support/knowledgebase/1030/
> >
> > Solution Number: 1030
> > Title: Error message: "Out of memory"
> > Platform: All Platforms
> > Applies to: All Products
> > Versions: 3.3, 3.4
> > Created: April 29, 2008
> > Last Modified: August 15, 2008
> > Categories: Solver, Postprocessing, Error Messages
> > Keywords: memory, geometry, mesh
> > Description
> >
> > The error message "Out of memory" occurs mostly on 32-bit platforms,
> > due to the inherent limit in memory address space. We recommend a
> > 64-bit system (for example Windows XP 64-bit Edition, Vista 64-bit
> or
> > a 64-bit Linux version) for any user with sizable models. For those
> > users who are still restricted to a 32-bit platform, this Knowledge
> > Base solution will give some guidance how to get the most out of
> your
> > system.
> > Introduction
> >
> > A 32-bit processor system (for example Windows XP) can potentially
> > allocate up to 4 GB of memory, but in most practical cases only 1.5
> GB
> > due to operating system footprint. This is regardless of how big you
> > set the swap space. Some 32-bit operating systems require special
> > settings to be able to use high amounts of memory.
> > Software Settings
> >
> > There are several ways of increasing the available memory for the
> solvers.
> > Tuning the Java heap size
> >
> > Of the available memory (RAM and virtual memory), one section, the
> > Java heap, is reserved for Java and will be used for graphics and
> > postprocessing. The rest will be available for meshing and solving.
> If
> > the out-of-memory message appears during the solution progress, you
> > can decrease the Java heap size. If you get out-of-memory during
> > postprocessing, increase the Java heap.
> >
> > On Windows, modify the file COMSOL34/bin/comsol.opts and on
> > Sun/Linux/Mac OSX, modify the file COMSOL34/bin/comsol. Change the
> > line MAXHEAP=256m to for example MAXHEAP=128m. You need to restart
> > COMSOL for the change to apply.
> > Running client-server mode
> >
> > Sometimes it can be favorable to run client/server mode because a
> > separate server has less memory fragmentation problems. If you want
> to
> > change the Java heap on a COMSOL server, follow the intstructions
> > above but modify the MAXHEAPSERVER line instead.
> > Running COMSOL with MATLAB
> >
> > Similarly, if you run out of memory while saving an mph-file from
> the
> > COMSOL with MATLAB, change the value of the MAXHEAPSERVER line.
> > Virtual Memory and Swap Space for 32-bit architecture
> >
> > Increasing the swap file size on the system is only interesting if
> you
> > can live with the notable slowness in operation that occurs as soon
> as
> > the hard disk swapping starts. In many cases, hard disk swapping is
> > not an option.
> >
> > In Windows XP, you only have 2 GB of virtual address space available
> > initially for a user process. This memory space is also sometimes
> > fragmented by shared libraries. On Linux, Sun, and Mac, you
> typically
> > get between 3-4 GB of virtual address space available for your
> > process. This address space is usually not fragmented.
> > 3 GB switch
> >
> > COMSOL Multiphysics supports the option in Windows XP Professional
> and
> > Windows 2003 Server to have 3 GB of virtual address space available
> > for user processes. This reduces the available address space for the
> > operating system to 1 GB. To access it you must boot the system
> using
> > an additional boot parameter. The following example shows how to
> > enable application memory tuning by adding the /3GB parameter in the
> > boot.ini file:
> >
> > Caution: Only add the /3GB switch, shown in boldface below. Do not
> > copy the full lines below into your boot.ini, since the parameter
> > values may be different for different systems. Please note that the
> > file boot.ini is critical to booting your system. If you change the
> > partition numbers, your computer will fail to boot and you cannot
> > recover the system without a system restore disk.
> >
> > To open the boot.ini file on Windows XP Professional, right-click My
> > Computer, select the Advanced tab, go to the lower section Startup
> and
> > Recovery, click Settings. In the new dialog box, click Edit.
> >
> > [boot loader]
> > timeout=30
> > default=multi(0)disk(0)rdisk(0)partition(2)\WINNT
> > [operating systems]
> > multi(0)disk(0)rdisk(0)partition(2)\WINNT="????" /3GB
> >
> > The "????" above can be the name of your operating system for
> example
> > "Microsoft Windows XP Professional".
> >
> > Some users report that Vista 32-bit also can benefit from a 3 GB
> > setting. This is not tested by us. To change the setting, run the
> > command bcdedit /set IncreaseUserVa 3072 as an administrator at the
> > command prompt. To turn off the 3 GB switch, run
> bcdedit /deletevalue
> > IncreaseUserVa.
> > A Note about Memory Monitoring on 32-bit systems
> >
> >
> > Especially in 3D modelling, extensive memory usage urges some extra
> > precautions. The "Out of Memory"-problem occurs whenever COMSOL
> > Multiphysics tries to allocate an array which does not fit
> > sequentially in memory. It is common on 32-bit systems that the
> amount
> > of available memory seems large enough for the array—but there may
> > exist no continuous block of that size due to fragmentation. If you
> > for example look in the task manager of Windows, this may have the
> > effect that you can't see any high memory allocation, and get "out
> of
> > memory" anyway.
> >
> > The "Memory Usage" column in the Windows task manager can also be
> > misleading, because it only shows the currently swapped portion. A
> > better indicator of total usage can be found like this (Win2000,
> > WinNT, Win XP, Windows Vista):
> >
> > 1. Press Ctrl-Alt-Delete to bring up the Task Manager.
> > 2. Go to the "processes" tab.
> > 3. From the View menu, choose Select Columns.
> > 4. Select the Virtual Memory Size (in Windows Vista: "Commit Size")
> > check box.
> > 5. Now find the comsol.exe process that corresponds to the COMSOL
> > Multiphysics process in the process list and look in the "VM Size"
> > column. This shows a better value for the actual memory used.
> >
> > See also: Knowledge Base solution 866 for hardware tips, Knowledge
> > Base solution 830 about memory intensive models.
> >
>

2a.

error 4100

Posted by: "Saskia Roels" saskiaroels@yahoo.com   saskiaroels

Tue Jan 6, 2009 5:52 am (PST)

hello everyone,

i am a new member of the group and just starting with comsol modeling. unfortunately i am facing my first problem already and i hope someone can help me.
as it is right now i am able to refine my mesh until a certain level and whenever i want to refine it more i get the following error:

Error: 4100
Failed to generate mesh for subdomain.
- Subdomain: 1
Internal error in advancing front mesher.

does anyone know what it means and what i can do to overcome this error?

Thanks a lot!
saskia.

Recent Activity
Visit Your Group
Yahoo! Finance

It's Now Personal

Guides, news,

advice & more.

Drive Traffic

Sponsored Search

can help increase

your site traffic.

Ads on Yahoo!

Learn more now.

Reach customers

searching for you.

Need to Reply?

Click one of the "Reply" links to respond to a specific message in the Daily Digest.

Create New Topic | Visit Your Group on the Web

沒有留言: